Module Pool

  • May- 2020 -
    3 May

    SUB SCREEN Demo IN MODULE POOL PROGRAM

    Description: Sub screens normally used to do all the task in a single screen without navigating to other screens. Sub…

    Read More »
  • 3 May

    CHAIN-ENDCHAIN

    Usually in Input screen, whenever the user gives an input and their is no record present in the DB, users’…

    Read More »
  • 3 May

    MODULE POOL PROGRAM – AT EXIT COMMAND

    Usually if the screen contains any required or mandatory input field & we run the Module pool program, the screen…

    Read More »
  • 3 May

    MODULE POOL PROGRAM – ON CHAIN-REQUEST

    DATA : N1 TYPE i. DATA : N2 TYPE i. DATA : N3 TYPE i. DATA : res TYPE i. DATA : ok_code TYPE sy-ucomm. MODULE status_9000 OUTPUT. *  SET PF-STATUS ‘xxxxxxxx’. *  SET TITLEBAR ‘xxx’. ENDMODULE.                 ” STATUS_9000  OUTPUT MODULE user_command_9000 INPUT. CASE ok_code. WHEN ‘ADD’. CALL  SCREEN 9001. ENDCASE. ENDMODULE.                 ” USER_COMMAND_9000  INPUT MODULE status_9001 OUTPUT. *  SET PF-STATUS ‘xxxxxxxx’.…

    Read More »
  • 3 May

    MODULE POOL PROGRAM – ON CHAIN-INPUT

    DATA : N1 TYPE i. DATA : N2 TYPE i. DATA : N3 TYPE i. DATA : res TYPE i. DATA : ok_code TYPE sy-ucomm. MODULE status_9000 OUTPUT. *  SET PF-STATUS ‘xxxxxxxx’. *  SET TITLEBAR ‘xxx’. ENDMODULE.                 ” STATUS_9000  OUTPUT MODULE user_command_9000 INPUT. CASE ok_code. WHEN ‘ADD’. CALL  SCREEN 9001. ENDCASE. ENDMODULE.                 ” USER_COMMAND_9000  INPUT MODULE status_9001 OUTPUT. *  SET PF-STATUS ‘xxxxxxxx’.…

    Read More »
  • 3 May

    MODULE POOL PROGRAM – ON REQUEST

    data : N1 type i. data : N2 type i. data : ok_code type sy-ucomm. module STATUS_9000 output. *  SET PF-STATUS ‘xxxxxxxx’. *  SET TITLEBAR ‘xxx’. endmodule.                 ” STATUS_9000  OUTPUT module USER_COMMAND_9000 input. CASE OK_CODE. WHEN ‘SHOW’. CALL  SCREEN 9001. ENDCASE. endmodule.                 ” USER_COMMAND_9000  INPUT module STATUS_9001 output. *  SET PF-STATUS ‘xxxxxxxx’. *  SET TITLEBAR ‘xxx’. N2 = N1. endmodule.                 ” STATUS_9001  OUTPUT…

    Read More »
  • 3 May

    MODULE POOL PROGRAM – ON INPUT

    Data : N1 type i,       N2 type i,      ok_code type sy-ucomm. module STATUS_9000 output. *  SET PF-STATUS ‘xxxxxxxx’. *  SET TITLEBAR ‘xxx’. endmodule.                 ” STATUS_9000  OUTPUT…

    Read More »
  • 3 May
    Photo of Simple MODULE POOL PROGRAM

    Simple MODULE POOL PROGRAM

    Step-1. Execute SE80. Choose Program And Give a Name ( zmp_test1 ) and press Enter. Step2. Press Yes. Step -3.…

    Read More »
Back to top button
Close

Adblock Detected

Please consider supporting us by disabling your ad blocker